* @file GoAnalog.h
|
|
* @brief Declares the GoAnalog class.
|
|
*
|
|
* @internal
|
|
* Copyright (C) 2016-2021 by LMI Technologies Inc.
|
|
* Licensed under the MIT License.
|
|
* Redistributed files must retain the above copyright notice.
|
|
*/
|
|
#ifndef GO_SDK_ANALOG_H
|
|
#define GO_SDK_ANALOG_H
|
|
|
|
#include <GoSdk/GoSdkDef.h>
|
|
|
|
/**
|
|
* @class GoAnalog
|
|
* @extends kObject
|
|
* @ingroup GoSdk-Analog
|
|
* @brief Represents Analog output settings.
|
|
*/
|
|
typedef kObject GoAnalog;
|
|
|
|
|
|
/**
|
|
* Gets the event which triggers this output to fire.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return The output event.
|
|
*/
|
|
GoFx(GoAnalogEvent) GoAnalog_Event(GoAnalog analog);
|
|
|
|
/**
|
|
* Set the event which triggers this output to fire.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param event The selected output event.
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetEvent(GoAnalog analog, GoAnalogEvent event);
|
|
|
|
/**
|
|
* Gets the number of measurement value source options.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Count of source options.
|
|
*/
|
|
GoFx(kSize) GoAnalog_OptionCount(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the measurement value source option at the specified index.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param index Source option index.
|
|
* @return Source option.
|
|
*/
|
|
GoFx(k32u) GoAnalog_OptionAt(GoAnalog analog, kSize index);
|
|
|
|
/**
|
|
* Selects a source type and source identifier for output.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param sourceId Output source identifier.
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetSource(GoAnalog analog, k32u sourceId);
|
|
|
|
/**
|
|
* Gets the selected source identifier.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Selected source identifier.
|
|
*/
|
|
GoFx(k32u) GoAnalog_Source(GoAnalog analog);
|
|
|
|
/**
|
|
* Clears the currently selected source identifier.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_ClearSource(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the minimum valid value for CurrentMin, CurrentMax and CurrentInvalid settings.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Minimum valid current value (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentLimitMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the maximum valid value for CurrentMin, CurrentMax and CurrentInvalid settings.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum valid current value (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentLimitMax(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the minimum current output level.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param min Minimum current output level (mA).
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetCurrentMin(GoAnalog analog, k64f min);
|
|
|
|
/**
|
|
* Gets the minimum current output level.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Minimum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the minimum allowable current output level to be set for the minimum current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMinLimitMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the maximum allowable current output level to be set for the minimum current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMinLimitMax(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the maximum current output level.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param max Maximum current output level (mA).
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetCurrentMax(GoAnalog analog, k64f max);
|
|
|
|
/**
|
|
* Gets the maximum current output level.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMax(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the minimum allowable current output level to be set for the maximum current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMaxLimitMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the maximum allowable current output level to be set for the maximum current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentMaxLimitMax(GoAnalog analog);
|
|
|
|
|
|
/**
|
|
* Enables the current output level associated with an invalid measurement.
|
|
* When this is disabled, the output value will be held constant on an invalid measurement
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param enable kTRUE to enable, or kFALSE to disable.
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_EnableCurrentInvalid(GoAnalog analog, kBool enable);
|
|
|
|
/**
|
|
* Gets the status of the invalid current enabled option
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Whether invalid current is enabled for this output.
|
|
*/
|
|
GoFx(kBool) GoAnalog_CurrentInvalidEnabled(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the current output level associated with an invalid measurement.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param invalid Invalid output current (mA).
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetCurrentInvalid(GoAnalog analog, k64f invalid);
|
|
|
|
/**
|
|
* Gets the current output level associated with an invalid measurement.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Invalid current level (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentInvalid(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the maximum allowable current output level to be set for the invalid value current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentInvalidLimitMax(GoAnalog analog);
|
|
|
|
/**
|
|
* Gets the minimum allowable current output level to be set for the invalid value current.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum current output (mA).
|
|
*/
|
|
GoFx(k64f) GoAnalog_CurrentInvalidLimitMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the measurement value associated with the minimum output current value.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param min Minimum measurement value (units are measurement dependent).
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetDataScaleMin(GoAnalog analog, k64f min);
|
|
|
|
/**
|
|
* Gets the measurement value associated with the minimum output current value.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Minimum measurement value (units are measurement dependent).
|
|
*/
|
|
GoFx(k64f) GoAnalog_DataScaleMin(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the measurement value associated with the maximum output current value.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param max Maximum measurement value (units are measurement dependent).
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetDataScaleMax(GoAnalog analog, k64f max);
|
|
|
|
/**
|
|
* Gets the measurement value associated with the maximum output current value.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return Maximum measurement value (units are measurement dependent).
|
|
*/
|
|
GoFx(k64f) GoAnalog_DataScaleMax(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the delay from exposure until output is triggered, in units based on GoDomain
|
|
* mm when GoDomain is distance, uS when GoDomain is time.
|
|
*
|
|
* The delay is ignored when GoDomain is Immediate or when output is Software triggered.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param delay The delay (uS or mm)
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetDelay(GoAnalog analog, k64s delay);
|
|
|
|
/**
|
|
* Gets the output delay.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return The output delay (uS or mm).
|
|
*/
|
|
GoFx(k64s) GoAnalog_Delay(GoAnalog analog);
|
|
|
|
/**
|
|
* Sets the output delay domain.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param delayDomain Output delay domain.
|
|
* @return The output delay domain (time or encoder value).
|
|
*/
|
|
GoFx(kStatus) GoAnalog_SetDelayDomain(GoAnalog analog, GoOutputDelayDomain delayDomain);
|
|
|
|
/**
|
|
* Gets the output delay domain.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return The output delay domain.
|
|
*/
|
|
GoFx(GoOutputDelayDomain) GoAnalog_DelayDomain(GoAnalog analog);
|
|
|
|
/**
|
|
* Enables or disables the scheduler for this output.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @param enabled kTRUE to enable, kFALSE to disable
|
|
* @return Operation status.
|
|
*/
|
|
GoFx(kStatus) GoAnalog_EnableSchedule(GoAnalog analog, kBool enabled );
|
|
|
|
/**
|
|
* Gets the enabled state of the scheduler for this output.
|
|
*
|
|
* @public @memberof GoAnalog
|
|
* @version Introduced in firmware 4.0.10.27
|
|
* @param analog GoAnalog object.
|
|
* @return kTRUE if the scheduler is enabled; kFALSE otherwise.
|
|
*/
|
|
GoFx(kBool) GoAnalog_ScheduleEnabled(GoAnalog analog);
|
|
|
|
#include <GoSdk/Outputs/GoAnalog.x.h>
|
|
|
|
#endif
|